7×24 服务热线Sales hotline 400-151-0319 海外 / 手机(微信同号)Overseas / mobile (WeChat ID) +86 150-7688-0801 厂址Address:河北省邢台市南宫市经济开发区(西区)朝阳街2号No.2 Chaoyang St, West Zone, Nangong EDZ, Xingtai, Hebei
首页Home/产品中心Products/水浴式气化器Water-bath vaporizer
Electric, steam or hot-water heat source

水浴式气化器Water-bath vaporizer

用热水浴把低温液体加热气化,出力不随气温波动,是北方冬季与高负荷场合的补热主力。Water bath delivers stable output regardless of ambient — the winter trim heater.

3heat sources电/蒸汽/热水Heat sources
稳定出力不受气温影响Weather-independent
复热与空温式串接Series with ambient
水浴式气化器
01 / Overview

产品概述Product overview

水浴式的价值就一条:它不看天气。空温式在 −20℃ 时掉到六成出力,水浴式仍是额定。北方 LNG 站、连续生产的工业用户、以及要求出口温度恒定的场合,水浴式不是备选而是必需。热源三选一:电加热(无锅炉的站点)、蒸汽(有蒸汽源的工厂)、热水(锅炉或余热),换热结构为壳管式或盘管浸没式。A water bath holds rating regardless of weather; heat can be electric, steam or hot water.

设计要点在温控与防冻:出口温度设闭环调节,水温低限联锁停泵,避免低温液体进壳程造成冻结;水箱做保温与补水,户外安装另加防冻排空。Closed-loop outlet temperature control with low-limit interlock and drain-down for outdoor installation.

水浴式气化器
水浴式气化器:水温、液位与超压保护各自独立,冬季不需另备热源。Water-bath vaporizer: separate water-temperature, level and overpressure protection; no extra heat source in winter.
A / Working principle

工作原理:热水浴里的稳定出力Working principle: steady duty inside a hot water bath

水浴式气化器的换热管浸在热水里,热水由电加热、蒸汽盘管或燃气热水炉提供。低温液体在管内吸热气化,管外用热水包围,换热系数远高于空气,因此同样体积的出力大得多,而且不随气温波动。The vaporiser's tubes sit in a hot water bath heated by electric elements, a steam coil or a gas-fired water heater. Cryogenic liquid vaporises inside the tubes while water surrounds them; the heat-transfer coefficient is far above that of air, so output per unit volume is much higher and does not follow ambient temperature.

水温控制是运行的核心:水温太低出力不足,太高则能耗上升、结垢加快、甚至让水温接近沸点产生大量蒸汽。通常按厂家推荐区间运行,并配温度控制与低液位保护——水位不足会让加热元件干烧。Water temperature is the operating core: too low and duty falls short, too high and energy, scaling and steam losses climb. Run within the maker's band, with temperature control and low-level protection — a low level exposes the elements to dry firing.

与空温式组合是常见方案:平时空温运行省电,冬季或高负荷时水浴补热。这套组合在北方项目里几乎是标配,投资与运行成本都比单一放大设备合理。Pairing with ambient units is common: ambient runs in the mild season at near-zero running cost, and the water bath trims in winter or at high load. In northern projects this combination is close to standard, and cheaper in both capital and running cost than a single oversized unit.

02 / Structure

结构组成What is on the skid

01
壳体与水箱:保温水箱、壳管或盘管换热面。Insulated bath with shell-and-tube or coil surface.
02
加热元件:电加热管组 / 蒸汽盘管 / 热水盘管。Electric elements, steam or hot-water coils.
03
温控系统:温度传感器 + 调节阀 / 固态继电器。Sensors with control valve or SSR.
04
补水与排空:补水口、排污口、防冻排空阀。Fill, drain and freeze-protection valves.
05
液位与联锁:低液位停机,防干烧。Low-level cut-off against dry firing.
06
撬体与接线:防爆接线盒、接地。Ex junction box, earthing.
03 / Advantages

核心优势Why this design

  • 出力稳定:不受环境温度影响,冬季不降容。Stable output in winter.
  • 三种热源可选:按现场能源条件定,不强制配电。Three heat sources to suit site energy.
  • 与空温式串接:平时空温、峰时水浴,能耗最优。Series with ambient for lowest energy.
  • 温控闭环:出口温度可设定并保持。Closed-loop temperature control.
Core / 产品优势

四件做到位,设备才站得稳Four things done right

01换热选型

翅片管束按气化量与当地冬季工况核算,低温段材料按 -196℃ 选。

02整撬出厂

翅片、撬架、管路与调压计量段厂内组对试压,现场只接进出口与电源。

03安全兜底

超压切断与放散、出口温度低限报警、自动运行,异常先切后报。

04品质留痕

每台带检验试验状态标识、检验记录与检验报告,跟设备一起交到现场。

Gallery / 产品图片

产品实拍Product photos

水浴式汽化器 · 筒体与水浴换热 1

水浴式汽化器 · 筒体与水浴换热Water-bath vaporiser — shell and bath 点击图片放大查看。 Click to enlarge.

04 / Specification

技术参数Technical data

热源Heat source电加热 / 蒸汽 / 热水Electric / steam / hot water
换热形式Exchange壳管式 / 盘管浸没式Shell-tube or immersed coil
出口温度Outlet temp.按工况设定,闭环控制Set point, closed loop
适用介质MediumLNG / LO₂ / LN₂ / LAr / CO₂LNG / LO₂ / LN₂ / LAr / CO₂
控制Control温度联锁、低液位停机Temperature interlock, low-level cut-off
安装Mounting室内或户外保温型Indoor or insulated outdoor

表中为该系列典型配置。项目流量、介质与进出口压力不同时按工况单独设计,参数以合同技术文件为准。Typical configuration; units are engineered per duty and the contract data sheet governs.

B / Selection

选型与计算要点Selection points

01
热负荷与热源匹配 先算热负荷(流量 × 焓差),再选热源:电加热安装简单、运行成本高;蒸汽需要蒸汽源;燃气热水炉运行便宜但涉及燃烧与排烟审批。三种方式的初投资与运行费差别很大,要按年运行小时算总成本。Duty and heat source Compute duty from flow × enthalpy difference, then choose the source: electric is simple to install but costly to run; steam needs a steam supply; a gas heater is cheap to run but brings combustion and flue approvals. Compare total cost over annual running hours.
02
水温与循环 水温控制精度直接影响出口温度稳定性。大容量水浴建议配循环泵与温度分层控制,避免局部过热与死水区。Water temperature and circulation Temperature control accuracy drives outlet stability. Large baths benefit from a circulation pump and stratified control to avoid hot spots and dead zones.
03
结垢与水质 水浴长期运行会结垢,传热变差。要设计排污与补水,必要时加软化处理;电加热元件结垢后极易过热损坏。Scaling and water quality Long service scales the bath and degrades heat transfer. Provide blow-down and make-up, soften the water if needed; scaled elements overheat and fail.
04
保冷与防冻 水浴本体要保温,停机时防止水结冰撑裂盘管或壳体。北方项目要配电伴热或保证循环。Insulation and freeze protection The bath is insulated, and when stopped the water must not freeze and split coils or shell. Northern sites need tracing or continued circulation.
05
控制与保护 低液位、超温、缺水、加热元件故障都要报警并切断加热;出口低温报警与下游调压联锁。Controls Low level, over-temperature, water loss and element failure must alarm and cut the heater; a low outlet temperature alarm interlocks with the downstream regulator.
05 / Duty

适用工况Typical duties

北方 LNG 气化站补热Northern LNG stations连续生产工业用户Continuous industrial users充装站高压气化High-pressure filling出口温度要求恒定的工艺Processes needing constant temperature
Fit / 适用与边界

适合什么工况,什么情况不适用Where it fits, and where it does not

这套设备适合Best for

  • 出力稳定,不受气温影响Stable output regardless of ambient temperature
  • 可配套电、蒸汽或热水多种热源Electric, steam or hot-water heat sources
  • 适合北方冬季与高负荷连续供气Suits northern winters and continuous high load
  • 出口温度可控,避免低温脆断Controlled outlet temperature avoids cold embrittlement

需要提前确认的边界Check before ordering

  • 需要热源与运行成本,电加热功率较大Needs a heat source; electric heating draws significant power
  • 筒体与盘管需定期除垢、检查Shell and coil need descaling and inspection
  • 启动升温有时间,不适合瞬时启停Warm-up takes time; not ideal for instant cycling
Configuration / 标准配置

标准配置Standard configuration

筒体Shell水浴筒体,内置换热盘管,介质走管内Water-bath shell with immersed heat-transfer coil
热源Heat source电加热、蒸汽盘管或燃气热水,按现场能源条件选Electric, steam coil or gas-fired hot water, by site utilities
循环Circulation循环泵维持浴温均匀,减小进出口温差Circulation pump keeps bath temperature uniform
温控Control温度控制器 + 液位计,低液位与超温联锁Temperature controller and level gauge with low-level and over-temperature interlocks
保温Insulation筒体与管路保温,减少散热损失Shell and piping insulated to limit heat loss
阀组与排污Valves and drain进出口阀、安全阀与排污阀Inlet / outlet valves, relief and drain
撬体Skid整体撬装,检修通道与爬梯按现场配置Skid-mounted with access and ladder as required

以上为常规配置,实际随机组按工况与用户管网条件确定,可按需增减。Standard scope shown; final scope is set by duty and network conditions, and can be adjusted.

Components / 主要零部件

主要零部件Main components

水浴筒体Bath shell容纳热水,为盘管提供换热环境Holds the hot water around the coil
换热盘管Heat-transfer coil介质在管内流动,与热水换热Medium flows inside, exchanging heat with the bath
电加热器 / 蒸汽盘管Heater / steam coil提供热源,维持浴温Heat input to hold bath temperature
循环泵Circulation pump维持浴温均匀Keeps bath temperature uniform
温控与液位计Controller and level gauge控温、低液位保护Temperature control and low-level protection
安全阀与排污阀Relief and drain超压保护与定期排污Overpressure protection and periodic drain

零部件的品牌与型号按项目技术要求与用户指定品牌确定,页内不限定具体厂家。Brand and model are fixed by project specification and the user's approved vendor list.

C / FAQ

常见问题FAQ

水浴式比空温式费电吗?Does a water bath cost more to run?

单位热量上是的,但只在需要补热的时段运行,全年算下来往往比“空温放大到最冷天”更省。关键在运行策略。Per unit of heat, yes — but it only runs when trim is needed, so annual cost is often below oversizing the ambient bank for the coldest day. Operating strategy decides.

水温上不去怎么办?Why won't the water heat up?

查加热功率是否足够、是否有结垢、循环是否正常、低液位保护是否误动作。冬季进水温度低时启动时间也会变长。Check heater capacity, scaling, circulation, and whether low-level protection is tripping. Cold make-up water also lengthens start-up in winter.

可以干烧吗?Can it run dry?

绝对不可以。低液位保护必须可靠并定期试验;干烧会瞬间损坏加热元件,甚至引发事故。Never. Low-level protection must be reliable and periodically tested; dry firing destroys elements instantly and can be dangerous.

停用一段时间要注意什么?What if it stands idle?

排空或保持循环与伴热,防止冻结;重新投用前检查水质、水位与元件绝缘。Drain, or keep circulation and tracing on to prevent freezing; before restart check water quality, level and element insulation.

出口温度波动大是什么原因?Why does outlet temperature swing?

多为水温控制不稳或流量波动大。先看水浴温度曲线,再看下游用气是否间歇性大幅变化。Usually unstable bath temperature or swinging flow. Look at the bath temperature trend, then at whether downstream demand is intermittent.

07 / Related

同类设备Related equipment

把你的工况发过来,我们出选型表Send your duty, we return a selection sheet

需要提供:介质、最大/最小流量、进口压力、出口压力、现场热源(电/热水/蒸汽)、安装场地条件。We need medium, min/max flow, inlet and outlet pressure, available heat source and site conditions.